Sign In | Join Free | My wneducation.com |
|
Place of Origin : China
Brand Name : Ascentet
Model Number : OEM
MOQ : Negotiable
Price : $1,000.00-$2,000.00
Packaging Details : Standard Carton Box or Wooden Case
Delivery Time : 5-8 work days
Payment Terms : T/T, L/C
Certification : CE FDA
Supply Ability : Enough stock
User's Manual : Included
Type : Breathing Apparatus
Power supply : AC110~240V, 50Hz/60Hz, 65VA
Instrument classification : Class II
Measurement range : 20-45℃
Pulse range : 0-300bpm
Pulse accuracy : ±2bpm
Product Name : Ventilator Breathing Machine
Recovery ICU Pediatric Anaesthesia Portable Medical Ventilator Brething Machine
Description
Ventilator is a model of multi-purpose life-support machine. This machine uses the air operated electric control, the microcomputer technology. Selects imports the primary device to guarantee the equipment movement stably reliable. Colored (TFT) the screen demonstrates each kind of examination and the establishment parameter, which is a section of ideal breath treatment plant. It is suitable in all different levels of hospitals for internal medicine of surgery, gynecology, pedology, first aid, ICU and so on which are administrative offices equipments.
Main technical parameters
Ventilator | |
Display mode | 10.4-inch High-definition TFT color LCD screen display |
Ventilation mode | VCV,PCV,SIMV,PSV,PSV+SIMV,CPAP |
Ventilation function | PEEP,SIGH ,standby ,IP,IRV |
Ventilation parameters | |
Tidal volume | 20~2000ml |
Rate | 2~120bpm |
SIMV rate | 2~20bpm |
I:E | 4:1~1:8 |
Inspiratory trigger pressure | -10~20 cmH2O |
Flow trigger sensitivity | 1-20L/min |
PEEP | 0~25 cmH2O |
Pressure control | 3~60cmH2O |
Presure limit | 5~60 cmH2O |
Pressure slope | 1~10 gear |
Flow rate setting | 1~10 gear |
Expiratory trigger sensitivity | 10%~90% |
Time control | 1~10s |
SIGH | 1.5 times the inspiratory time(60-120 times adjustable) |
Inspiratory platform | 0~50% |
Oxygen concentration | 21%~99% |
Parameters for ventilation monitoring
Oxygen Concentration alarm | |
Upper limit setting range | 21%~99% |
Low limit setting range | 15%~80% |
Airway pressure alarm | |
Upper limit setting range | 1~60 cmH2O |
Low limit setting range | 0~50 cmH2O |
Minute ventilation volume alarm | |
Upper limit setting range | 1~30L/min |
Low limit setting range | 0~20L/min |
Tidal volume | |
Upper limit setting range | 10~2000ml |
Low limit setting range | 0~1800ml |
Respiratory rate | |
Upper limit setting range | 10~99bPm |
Low limit setting range | 0~50 bPm |
Sustained high-pressure alarm |
it will give alarm when stress have consistently been higher than 30 cmH2O |
Suffocation alarm | |
Gas shortage alarm | |
Low pressure of Oxygen alarm | |
Low pressure of Air alarm | |
Power alarm | |
Intubation off alarm | |
Battery voltage alarm | |
Power | AC 220V±10% 50Hz±1Hz UPS, Storage Battery |
Manipulator | |
Air compressor with “standby” function |
![]() |